Analytical and Clinical Assessment of a Portable, Isothermal Recombinase Polymerase Amplification (RPA) Assay for the Molecular Diagnosis of Urogenital Schistosomiasis
Name:
Analytical and Clinical Assessment ...
Size:
1.366Mb
Format:
PDF
Description:
Published Version
Average rating
Cast your vote
You can rate an item by clicking the amount of stars they wish to award to
this item.
When enough users have cast their vote on this item, the average rating will also be shown.
Star rating
Your vote was cast
Thank you for your feedback
Thank you for your feedback
Authors
Archer, JohnBarksby, Rebecca
Pennance, T
Rostron, Penelope
Bakar, Faki
Knopp, Stefanie
Allan, F
Kabole, Fatma
Ali, Said M
Ame, Shaali M
Rollinson, D
Webster, BL
Issue date
2020-09-11Submitted date
2020-07-31Subject Terms
Urogenital schistomiasisSchistosoma haematobium
point-of-care
diagnosis
recombinase polymerase amplification (RPA)
control
surveillance
elimination
Metadata
Show full item recordAbstract
Accurate diagnosis of urogenital schistosomiasis is crucial for disease surveillance and control. Routine diagnostic methods, however, lack sensitivity when assessing patients with low levels of infection still able to maintain pathogen transmission. Therefore, there is a need for highly sensitive diagnostic tools that can be used at the point-of-care in endemic areas. Recombinase polymerase amplification (RPA) is a rapid and sensitive diagnostic tool that has been used to diagnose several pathogens at the point-of-care. Here, the analytical performance of a previously developed RPA assay (RT-ShDra1-RPA) targeting the Schistosoma haematobium Dra1 genomic region was assessed using commercially synthesised S. haematobium Dra1 copies and laboratory-prepared samples spiked with S. haematobium eggs. Clinical performance was also assessed by comparing diagnostic outcomes with that of a reference diagnostic standard, urine-egg microscopy. The RT-ShDra1-RPA was able to detect 1 × 101 copies of commercially synthesised Dra1 DNA as well as one S. haematobium egg within laboratory-spiked ddH2O samples. When compared with urine-egg microscopy, the overall sensitivity and specificity of the RT-ShDra1-RPA assay was 93.7% (±88.7–96.9) and 100% (±69.1–100), respectively. Positive and negative predictive values were 100% (±97.5–100) and 50% (±27.2–72.8), respectively. The RT-ShDra1-RPA therefore shows promise as a rapid and highly sensitive diagnostic tool able to diagnose urogenital schistosomiasis at the point-of-care.Citation
Archer J, Barksby R, Pennance T, Rostron P, Bakar F, Knopp S, Allan F, Kabole F, Ali SM, Ame SM, Rollinson D, Webster BL. Analytical and Clinical Assessment of a Portable, Isothermal Recombinase Polymerase Amplification (RPA) Assay for the Molecular Diagnosis of Urogenital Schistosomiasis. Molecules. 2020; 25(18):4175. https://doi.org/10.3390/molecules25184175Publisher
MDPI AGJournal
MoleculesType
Journal ArticleItem Description
Copyright: © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). The attached file is the published version of the article.NHM Repository
ISSN
1420-3049EISSN
1420-3049ae974a485f413a2113503eed53cd6c53
10.3390/molecules25184175
Scopus Count